Version 3.11 Build 55
Release Date: 4/13/2010
- Modified the various delete options under the right-click menus in the
various layout views.
- Made further changes to preventing other patients from bridging when in
the middle of different patient related functions in another patient (e.g.
capture dialog, open patient images dialog, capture video, layout saving,
print, print multiple, etc).
- Added new advanced export and import data correction utilities (Mass Data
Correction) in the Database Utilities menu.
- Added additional safety options to prevent the user from forcefully closing
a layout when it is still saving to a disk drive.
- "Stop Sensor Capture" button renamed to "Stop Series Capture".
- Added Global ID matching options where patient information is coordinated
based on the patient ID. This option is primarily used by large organizations
that bridge patient information over from a third party application.
- Made adjustments for when dealing with really, really large images. The
application could potentially run out of memory when doing image operations
on very large images or multiple large images. Virtualized memory added
when dealing with undo/redo operations on very large image operations.
Version 3.11 Build 55
Release Date: 4/7/2010
- Modified the various delete options under the right-click menus in the
various layout views.
Version 3.11 Build 52
Release Date: 3/11/2010
- Color labels now appear in grayscale images when: printing; full screen
view; floater view; copy to clipboard; spawned image documents.
- "Delete original" option now follows recycle bin setting.
- Tile indicators now displayed when working with layouts in the layout manager
and the "display tile tooth numbers" option is enabled.
- Tooth numbers have been added to the status bar when working with images
in a layout (e.g. single image view or tile selection).
- Patient sex and DOB have been added to the information displayed in the
various Advanced Patient Merge dialogs.
- Added the ability to assign an "auto import" source to a layout's tile.
This option additionally works when using the "automatically start series
acquisition" option.
- Added new "/w" option that enables a remote application to specify a named
windows event that will be signaled whenever an image is acquired or imported.
- New features added to prevent a patient from being bridged from a third
party application when the user is currently in a layout or image capture
context.
- Made is so fewer "user cancelled" messages are displayed when the user
cancels a layout acquisition and the option to display cancel messages is
disabled.
- Problem corrected where Auto Export can overwrite an already exported image
when the patient name has special characters in it.
- Problem corrected where the patient ID number and Sex columns were switched.
- Problem corrected when programmatically launching XrayVision very quickly
in a row when bridging patients can result in database access problems. This
can manifest itself as the patient not being seen or being added to the database
more than once.
- Problem corrected where resaving an image with the "apply storage scheme
to already saved images" can loose the converted image when converting from
STB to JPEG.
Version 3.11 Build 50
Release Date: 2/23/2010
- Corrected an issue with latency generated by additional information checking
when bridging patients from a third party application.
- Corrected an issue where the new tooth number indicators would not updated
when changing the tooth associations for an image in a layout.
Version 3.11 Build 49
Release Date: 2/18/2010
- Changing the patient name will now update the patient information in all
of the title bars.
- Corrected a problem where an image's thumbnail in a layout could reflect
the an older image when an image is deleted and then retaken in a new layout.
- The tile number indicators on each tile in a layout can now display the
tooth numbers associated with each tile. New option on Interface 2 can be
used to set it back to display the tile number. The new tooth number display
will also appear on layout printouts.
- The tile number indicators have been made smaller.
- Changes made to conflict between the patient information hiding and patient
information display options. New note added under the options tab to indicate
which one takes precedence.
- Corrected image flicker when resizing STB and STB16 images.
- New verbiage has been added to the Version Incompatibility dialog to reduce
the confusion concerning what the user should do to rectify the problem.
- Correction made to problem where patient thumbnails can stop updating on
the patient index when manually typing in a patient's name.
- New option added (enabled by default) to the General 2 tab to automatically
update the patient information associated with a layout when the patient
information
does not
match (e.g. a patient gets married and changes their name, patient ID number
is updated, etc). Previously the software would prompt the user concerning
that should be done.
- New handling added to allow the application to recover from corrupted LYO
files (the files that remember what size and positions the applications and
various windows were when the application was closed).
- Made changes to correct the issue with new installations where the DirectVideo
extension is used instead of a sensor when the user follows a certain capture
path the very first time they use the application.
- Added new options to permit image information to be placed in the footer
of an image when performing an AutoExport.
- "Stop Sensor Capture" button added to the bottom of the capture layout
dialog. This button can be used to abort a sensor capture instead of having
to click on the various sensor status dialogs and clicking Cancel, Abort
or the 'X' in the title bar of the dialog.
- New option added under the Interface 2 tab that remembers the last positioning
of a single image view when viewing a layout. This is used by individuals
that position the layout overview to one side of the window and the layout
single view on the other. When enabled this option automatically repositions
the windows in single image view to the previous positions used.
- Added a new option under the Interface 2 tab that allows the software to
automatically start the series when acquiring in a new layout. Previously,
the user had to initiate the series capture when a new layout is created.
- The Auto Import button on the layout capture screen will now automatically
start importing without prompting the user to acknowledge a dialog. A new
button beside the button has been added that will display the dialog and
perform the standard dialog based auto-import.
- Full screen mode and FloaterViews now automatically are in ZOOM mode instead
of PAN mode.
- Change made to prevent the conflict that can occur when multiple patients
are bridged from a 3rd party application at the same time and the Open Patient
Images or Patient Index is displayed. Previously, it would open multiple
dialogs that could lead to confusion concerning what patient is open.
- You can now do a Ctrl+V paste into a layout when a tile is selected instead
of clicking of one of the "take image from clipboard" options.
- The pop-up scroll bars that are displayed throughout the application have
been replaced with standard scroll bars.
- The Open Patient Images will now appear again if the patient is open and
they are then bridged again from a 3rd party application.
- Changes made to how patient information is updated when bridged from 3rd
party applications. The new handling additionally works with the patient's
DOB and sex.
- Tool tip have now been added over the tabs in the patient index. This provides
additional information for each patient and in addition is used when there
are similar patients tracked by the application.
- Adaptive Normalize macro has been changes so that user can now specify
the top and bottom margins.
- New Recycle Bin option added (enabled by default) to the General 2 tab.
Now when deleting images and/or patients they are moved to the Recycle Bin
instead
of being
deleted. Please note that if you are deleting images and/or patients from
a networked computer, the files/directories are saved in the LOCAL Recycle
Bin and not in the remote computer's Recycle Bin.
Version 3.11 Build 47
Release Date: 1/11/2010
- Made additional changes for handling of ArchiveIT logging.
- Added functionality to add patient files to the ToStore database that
have been imported via: Import Patient; new patients found during a Update
Patient Database.
Version 3.11 Build 44
Release Date: 1/6/2010
- Corrected a problem when exporting patient CD/DVD when specifying the XV
file format.
Version 3.11 Build 43
Release Date: 12/21/09
- Trial version licenses increased from 3 to 15.
Version 3.11 Build 41
Release Date: 12/3/09
- Option to make the ImageBar go vertically instead of horizontally.
- Added tool tips to the ImageBar.
- Touched up part of the ImageBar GUI.
- ImageBar now appears on the same monitor as the application instead of
the primary monitor on multiple-monitor systems.
- Option added to allow the display of both the adult and deciduous tooth
controls in the popup tooth control.
- Corrected where a user could still capture under Nobody even though the
option to prevent acquisition under Nobody was checked. This happened for
Quick Layout Captures and when the user directly select an acquisition from
an IDDLL.
- Added the ability to work with layouts in an "Inside the mouth out" capacity.
When in "inside-out" mode, various title bars and contexts are updated to
indicate the mode. Images are automatically flipped in this mode during acquisition.
The new options is located in the layout options (when defining a layout)
or when flipping an existing layout.
- Layout tile font changed to better handle displaying the tile's text on
various monitors.
- The "Taken From" text has been removed from the tile's text. The tiles
still display what modality they are to capture from; just the "Taken From"
text was removed.
Version 3.11 Build 40
Release Date: 12/2/09
- Added new option to layout captures: auto-import images.
Version 3.11 Build 38
Release Date: 9/29/09
- Improved drawing/update speed for layout drawing and display.
- Improved drawing/update when resizing an image's or layout's window.
- Added new auto-import feature that can more easily import/acquire images
from cameras and directories. The new feature automatically imports images
either as single images or directly into a layout.
Version 3.11 Build 32
Release Date: 9/1/09
- Added new tab to the capture single image dialog that permits selection
of a general TWAIN device that converts the returned image to a different
color scheme when the image is returned. For example, some TWAIN scanners
only return a full-color image even when scanning a grayscale image.
Version 3.11 Build 31
Release Date: 8/5/09
- Added a new option "Export Images" under the "Patient Utilities" menu that
permits the exportation of patient images without having to open them first.
- Made modifications to the new label tools.
- Corrected typo in the export menu.
- Made changes to accommodate different font sizes and texts that can appear
on the toolbar buttons.
- Added options and support for saving new images and modified images to
the ToStore database. This database is used by XVSync to facilitate faster
synchronization with other sites.
Version 3.11 Build 26
Release Date: 6/18/09
- Added translation corrections.
- Added ability to copy data tag search results to the clipboard.
Version 3.11 Build 25
Release Date: 6/3/09
- Added support for a Discipline.DAT file that identifies: Dental; Podiatry;
Veterinary. Support for this file will be utilized in future releases. Currently
its setting only modifies base option defaults and whether or not the Teeth
pop-up is displayed.
Version 3.11 Build 24
Release Date: 5/28/09
- Added additional multiple-language handling.
- Added additional directory creation and deletion options to the diagnostics.
- Added additional error checking when work-in-progress directories cannot
be created in the temporary WIP directory.
Version 3.11 Build 23
Release Date: 5/26/09
- Made a correction to version checking that incorrectly detected that the
new version of the ArchiveIT extension was an unsupported version.
Version 3.11 Build 22
Release Date: 4/24/09
- Made a correction to default custom toolbar handling. Corrected error where
the application may continue to ask if the default toolbar should be used.
Version 3.11 Build 21
Release Date: 4/20/09
- Added new Diagnostics option under the Help menu.
- Changed Suni's invoked 3D hardware button to recognize new direct capture
extension name of "Suni3D.DCDLL".
- Added new Diagnostic to determine if the WIP directory is intact.
- Updated floater view.
- Updated the export preview capability of the file dialog.
- Corrected problems with reallocating licenses of similarly named computers
(e.g. "Computer1" and "Computer11").
- Snap to grid operation when created layouts has been improved.
- Ability to select a category has been added when importing images.
- Naming conventions changed on the "Find Images By Date" dialog.
- Mouse over taken dates corrected in layout images.
- The layout's background color is now used in the Grid view and Single image
view.
- Selected tile's border color has been changed to make it easier to see.
This automatically changes based on the background color selected by the
user.
- Default toolbar button choice can now be set. This operates similarly to
setting the default configuration.
- New handling implemented when encountering corrupted taken dates with images.
- Variables have been added to predefined text labels. These variables are
automatically replaced with the respective information when placed in an
image (e.g. "%l, %f" will be replaced with the patient's last and first name).
- Corrected problem where unchecking the "Specified Text" options in various
print dialogs still printed the text as if the option was still enabled.
Additional corrections were made for the selected text font.
- Correction made when user manually selects a patient, then selects a different
patient using the keyboard. Previously it opened the manually selected patient
instead of the currently selected patient.
- Made changes so that the taken date and other information is transferred
to a Word document when spawning from a layout.
- Made various multiple-monitor corrections that may not have registered
user interactions when placed on a "negative" monitor (i.e. selecting the
print order when printing multiple images).
Version 3.11 Build 19
Release Date: 3/20/09
- Added new JPEG library support that handles much wider JPEG images .
- ImageBar command line option updated to allow two options. '/b' command
line option will allow creation of the patient if they do not exist. '/B'
option will not create the patient if they do not exist (it will do nothing).
- ProfSuni: new default patient demographic requirements settings; new 3D
logo.
- Updated the "path" field in the various image information dialogs so that
it shows the whole path (if the path was too long it would truncate the value)
and can now be copied to the clipboard.
- Corrected problem when double clicking on direct captured images (i.e.
3D volumes) on the patient's open image dialog would try and launch the image
twice.
- New ESC key handling that will no longer dismiss a dialog when the ESC
key is pressed to cancel an operation.
Version 3.11 Build 18
Release Date: 3/19/09
- Added file checking for files extracted from a zip file to ensure that
they were correctly extracted to the extraction directory.
Version 3.11 Build 17
Release Date: 2/25/09
- Vista drawing issue with pop-out dialogs corrected. This was due to Vista's
drawing of animated rectangle drawing which resulted in a SLOW animation.
- New installations default to Layout View instead of Single Image View.
- Monitor test pattern was added to the Tools menu.
- Copy to clipboard function with labels now keeps the labels in color for
grayscale images. Previous version converted everything into grayscale when
copying a grayscale image onto the clipboard.
- The default toolbox is no longer filled with all Arrow pointers.
- Implant labels are now oriented top-to-bottom by default instead of left-to-right.
- Layout indicators have been turned off on the Layout Floater View (when
viewing single images in a layout).
- The Floater View has been completely updated.
- The ImageBar has had minor cosmetic updates.
- Modified the 'E', 'B' and 'T' command line arguments to NOT automatically
create a patient if they do not exist. For more information, please refer
to the Command Line Arguments on-line reference.
- Correction made to Layout Floater View - it would on occasion not update
when made smaller.
- Additional tooth descriptions have been added (i.e. quadrant descriptors
of Q1, Q2, Q3, Q4) to minimize the amount of space some tooth displays required.
Version 3.11 Build 16
Release Date: 2/13/09
- Added option to find out all the registration numbers assigned to a particular
computer or installation. The "Display Registration Information" option is
available under the Help menu.
- Added feature that displays known image types when acquiring from a 3D
imaging device immediately after image acquisition.
- The patient information that is associated with each individual tile in
a layout is now updated when a layout is moved to another patient. Previously
the patient information was only updated for the overall layout until the
user opened and resaved a layout at which time the patient information is
updated for each image.
- Correction was made when the user selects a different database and then
closes the application. The software will now reopen the same database that
was opened the when the application was last closed.
- When a layout is opened in Single Image View, the first image is automatically
selected. Current behavior displayed an "X" until the user selected an image.
- Corrected a problem where the dates displayed for each tile in a layout
could revert to the modified date instead of the taken data associated with
an
image.
Version 3.11 Build 14
Release Date: 1/6/09
- Created a new "Could these be the same patient" interface. New dialog provides
clearer options and descriptions of what will happen for each option selected.
New options added to quickly update an existing patient with new patient
information.
- Added a new reason column in the "Could these be the same patient" dialog
that describes why each patient listed may be the same as the patient the
user is trying to open/create.
- Added a new option to print the patient list reports when performing the
Advanced Patient Merge function.
- Added ability to enable/disable individual merge items when performing
an Advanced Patient Merge.
- Added a new feature that checks if the connection to the database has been
lost (i.e. network problem, removable drive, etc) and displays an error indicating
when the connection has been lost. Previously the software would display
a "patient has been deleted" message when the
connection
is
lost.
- The first tile in a layout is no longer automatically selected when opening
an image in layout view.
- New features added to perform some of the image operations to ALL tiles
in a layout at the same time. If no tile is selected in a layout and the
user selects one of the viable image operations (i.e. invert), the software
will prompt the user if the image operation should be performed on all of
the images in the layout. Please note that due to various inputs required
to perform some image operations (such as sharpening), not all image operations
are available to be applied to all of the images at the same time.
- New "History" options added to the context sensitive menus. This new option
more easily enables the user to access the history of a tooth (previously
the user needed to click on the tooth or teeth in the Teeth pop-out dialog).
A new style dialog was added to display the images in the tooth history instead
of displaying the same dialog displayed by clicking on teeth in the Teeth
popup dialog.
- Compare function added to the historical view of tooth related images.
This compare can handle comparing 2, 3 or 4 images at the same time.
- Teeth associated with a layout has been modified to only include teeth
associated with the actual images in a layout. Previously the teeth associated
with a layout were based on the teeth associated with the tiles in a layout
(those teeth were reflected in the tooth associations even if a tile did
not have an image associated with it).
- A new, easier method of moving images around in a layout has been implemented.
Images now do NOT have to be dropped directly onto another tile when moving
the
images
around. When an image is dropped into open space a new tile is automatically
created to contain the image. If the user then moves the image from the new
tile to another tile in the layout the temporary tile is automatically
deleted. If the user leaves the image in the new tile, the new tile automatically
becomes a part of the layout. This new method also works when acquiring images
in a layout.
- The "Move Image To Another Tile" button on the layout's toolbar has been
changed to bring the user to a more advanced layout modification screen that
permits the user to more easily move images around the layout. This modification
screen supports the new temporary drag-and-drop tiles.
- By default, tiles can no longer be accidentally dragged around in the layout
view. A new option has been added that locks the layout tiles so they cannot
be moved by accident. Locking layouts can be disabled/enabled by a new button
on the layout's toolbar.
- Extraneous save messages for layouts have been removed.
- Correction made to moving layouts between patients. Previously the original
layout may not be deleted or removed from the old patient's record.
- Version Incompatibility window changed to include new wording and size.
- New options were added for STB images included in layouts that prevented
labels from being merged into the image when it was exported or copied. This
was due to the safety features that prevent STB images from being modified
that were not needed when exporting the images in other formats or copying
the images to the clipboard.
- Arrow keys when viewing single images in a layout have been changed (new
buttons added) to correctly move between tiles in the floating layout view.
The original arrow keys simply moved from one file to the next in the layout
regardless of what order they appeared in the layout itself. The new arrow
keys (marked with an "S") move to the next and previous image in the series.
- Internal changes made to correct for portions of the application that were
not being translated correctly in multiple-language versions of the software.
Version 3.11 Build 11
Release Date: 12/3/08
- Added new option to prevent image acquisition under "Nobody".
Version 3.11 Build 9
Release Date: 10/17/08
- Made corrections to calibration management in Label View dialogs.
- Prevented auto-switching to point mode when drawing free-hand lines.
- Made adjustments to the amount of time it takes to add any new entries
when recalling a patient from an archive.
- Made a correction to saving/exporting in the TIFF image format.
- Made a correction to incorrect license computation when applications are
not shut down correctly and a new computer is trying to allocate a new license.
- Made a correction to taken dates associated with newly imported images
that have their taken date changed immediately when they are imported into
the
software (and before they are saved to the database).
- Made a correction to handling real-time BC adjustment values for various
images contained in a layout when they are opened in single-image view. Previously
the last applied real-time BC was not applied to the image the next time
it was opened in single-image view.
- Added new options to allow changing the overall image type associated with
a layout.
- Made a correction to how measurement calibrations were handled in the Label
View.
Version 3.11 Build 6
Release Date: 10/2/08
- New controls integrated into the interface.
Version 3.11 Build 5
Release Date: 9/17/08
- Added ability to return all of the image that are acquired from a SED at
the same time instead of the user having to invoke the acquisition multiple
times.
- New version of the graphic button list control added.
- New scroller control added to the graphic button list control.
- Incremented the minor build number to 11 to reduce confusion with XrayVision
v3.1.
Version 3.10 Build 34
Release Date: 8/4/08
- Modified layout display capabilities for FloaterViews and Full screen displays
when a user selects one of those options when a single image is not selected
in a layout view.
- Removed the layout generation warning when displaying layouts that are
selected in the ImageBar. .
Version 3.10 Build 33
Release Date: 7/8/08
- Added new options under DataDrills to coordinate patient IDs in the database
with an external database.
- Made changed to the taken date that is associated with a single image that
is taken from a layout and transmitted through a TransIT extension (currently
the layout taken date is associated with the image).
Version 3.10 Build 32
Release Date: 5/27/08
- Made correction to the sex specification when passed on the command line
(i.e. "/p" command line option). Depending on the specification, then sex
was sometimes not utilized when specified on the command line.
Version 3.10 Build 31
Release Date: 5/15/08
- Added new command line options for third party application specifying auto
dataTAGs. Detailed information can be found in the Knowledge base.
- Reorganized the auto dataTAGs dialog.
- Added an additional custom auto dataTAGs field.
- Made the dataTAGs search dialog resizeable.
- Added additional search fields to the dataTAGs search dialog.
- Added patient search fields to the dataTAGs search dialog.
- Updated the options on the dataTAGs search dialog.
Version 3.10 Build 30
Release Date: 5/7/08
- Small change made to correct display of an implant's divisions (its diameter
and length values were reversed).
- Updated Apteryx's business address.
Version 3.10 Build 29
Release Date: 4/21/08
- Made a correction to a problem that was introduced into multi language
toolbars that caused Windows to abort the application when the multiple language
toolbar
was being loaded.
Version 3.10 Build 28
Release Date: 3/36/08
- Added capability of passing the image taken date to a TransIT extension.
Version 3.10 Build 27
Release Date: 3/17/08
- Made correction to exported layout where a single image is created.
Version 3.10 Build 26
Release Date: 3/13/08
- Added new options to display the taken dates in layouts (available in the
preferences). Depending on this setting, taken dates will be displayed below
each tile and other layout operations (i.e. copying to clipboard) will additionally
have the date displayed below each image.
- Added new options to automatically add a taken date label to new images
that are acquired.
Version 3.10 Build 24
Release Date: 2/26/08
- Made a change to remove median and smoothing functions when making a displayable
16-bit image.
Version 3.10 Build 22
Release Date: 1/16/08
- Updated short creation to automatically fill in the working/start-in directory.
- Maintenance build.
Version 3.10 Build 18
Release Date: 10/25/07
- Make correction to roll-over pop-ups.
- Added taken-date to information at the bottom of the open patient image
dialog.
- Added additional space at the end of the information at the bottom of the
open patient image dialog.
Version 3.10 Build 17
Release Date: 10/19/07
- Made correction to Merge Patient tool. Was broken by previous change to
facilitate easier moving of all associated files.
- Made update to Advanced Patient Merge tool to take into consideration formatting
of SS numbers. New merge function now considers different forms of SS numbers
to be the same (i.e. "111223333", "111-22-3333" and "111.22.3333").
Version 3.10 Build 16
Release Date: 10/18/07
- Added support for IDDLL to automatically specify their image types for
images returned to the main application.
Version 3.10 Build 15
Release Date: 10/3/07
- Corrected memory leak that can occur when capturing sensor images due
to new 16-bit capture implementation.
Version 3.10 Build 14
Release Date: 9/24/07
- Modified the "Update Patient FMap" function to additionally modify a file's
STAMP and TAG files. .
Version 3.10 Build 12
Release Date: 9/21/07
- Modified the "Update Patient FMap" function to modifiy the created dates
of the image files to reflect the taken date of the associated image.
Version 3.10 Build 11
Release Date: 9/6/07
- Further refinement of taken dates for layouts returned to third party
applications utilizing the command line bridge.
Version 3.10 Build 10
Release Date: 9/5/07
- Changed printing of taken date for a moved layout to utilize new method
of calculating layout taken dates.
Version 3.10 Build 8s
Release Date: 8/24/07
- Added functionality to allow sensor extensions to know when layout captures
are started and stopped.
- Taken date for layouts calculated better for those files that have been
manually copied and moved by the user.
- 16-bit operations corrected (saving new images, modifying images and then
resaving, auto-save).
Version 3.10 Build 7
Release Date: 8/9/07
- Made corrections to DOB restrictions when entering patient data.
Version 3.10 Build 6
Release Date: 8/5/07
- Reenabled 16-bit capture.
Version 3.9 Build 119
Release Date: 7/5/07
- Corrected wording on flip layout button in the layout editor.
- When opening a group whose patient information does not match the current
patient (i.e. image was moved to another patient or the patient data was
modified) now prompts the user if the patient information should be updated
in the file.
- Moving groups from patient to patient no longer looses the original creation
date of the layout if it was not specifically set by the user.
- Selection extraction from layouts now prompts the user if the extracted
image should be saved if the user did not already save it to the patient
record.
- Custom toolbar descriptions now appropriately update when the application
starts (i.e. macro and layout names now appear on the buttons).
- Application crash when a single user licensed computer has its main license
deleted corrected.
- Closing or resaving a group while the group is currently saving has been
prevented.
Version 3.9 Build 118
Release Date: 6/19/07
- Added options to automatically add various versions of the new Cosmetic
Imaging application to appear in the Other Applications list.
- Made changes to better handle parsing dates when sent to direct capture
extensions (i.e. DCDLL).
- Added new features to add support for image algorthm DLLs.
- Maintinance build.
Version 3.9 Build 117
Release Date: 5/15/07
- Made changes to progression capture does not overlap the task bar when
on the primary display.
Version 3.9 Build 116
Release Date: 5/9/07
- Enhanced support for ArchiveIT extension.
- Added new command line options.
Version 3.9 Build 114
Release Date: 4/6/07
- Added ability to select what images are to be exported when creating patient
CDs/DVDs
Version 3.9 Build 112
Release Date: 4/3/07
- CliniView: Added new toolbar button for when Novus imaging extension is
available
- Added new options for Direct Capture extensions to return single images
to the invoking application.
Version 3.9 Build 111
Release Date: 3/23/07
- Added new options under File Acquire menu that permits direct selection
of layouts.
- Added "Preferred Imaging Extension" options to menus (available when editing
a layout definition). Can be used to assign a default sensor extension to
a layout so that the user does not have to manually select which sensor is
to be used when capturing a layout.
Version 3.9 Build 110
Release Date:
???
- Made changes to correctly size dialogs when displayed on a smaller secondary
display on multiple monitor systems.
Version 3.9 Build 109
Release Date: 2/23/07
- Corrected problem with removing images from the DICOM storage list.
Version 3.9 Build 108
Release Date: 2/21/07
- Added DOB and Sex to options that can be specified for the command line
when invoking other applications.
Version 3.9 Build 107
Release Date: 2/19/07
- Replaced tile's orientation (vertical or horizontal) with an actual rotation
factor. Enables users to make vertical bitewing definitions.
- Changes made to support new DICOM support.
- Corrected JPEG/STB confusion problem.
- Support for mapping dental modalities to other modalities (i.e. CT cone
beam to CR modality).
Version 3.9 Build 105
Release Date: 1/23/07
- Addition of direct capture extensions (i.e. 3-D cone beam capture).
- Addtion of handling external file formats (i.e. 3-D cone beam files).
- Passing of worklist information to direct capture extensions.
Version 3.9 Build 102
Release Date: 12/28/06
- Corrected translation problems for menu items that have shortcut combinations
listed.
Version 3.9 Build 100
Release Date: 10/13/06
- Corrected an error that could have caused a crash when capturing layouts
while secure logging is enabled.
Version 3.9 Build 99
Release Date: 10/10/06
- Updated to export additional information when creating patient CD/DVD/Directory
for use for the new XVQuickView viewer application.
Version 3.9 Build 98
Release Date: 9/19/06
- Corrected missing DICOM information for some images when captured in a
layout using an IDDLL.
- Enhanced DICOM patient information associated with images during acquisition
in a layout.
Version 3.9 Build 96
Release Date: 7/18/06
- Added an option to allow striping of leading zeros on patient ID numbers.
Version 3.9 Build 95
Release Date: 7/6/06
- Made additional corrections to account for variations in names when a
middle name or initial exists.
- Maintenance rebuild.
Version 3.9 Build 94
Release Date: 7/6/06
- Made corrections to account for variations in names when a middle name
or initial exists.
Version 3.9 Build 93
Release Date: 6/1/06
- Modified how images are passed back and forth between XV and imaging extensions.
Windows incompatibilities lead to a possible crash on some computers when
passing images back and forth between the apps and extensions.
- Added additional checking to ensure proper versions for Gendex Imaging
and Soredex based extensions.
Version 3.9 Build 91
Release Date: 5/16/06
- Added options to allow bulk addition of auto dataTags to existing images.
Version 3.9 Build 90
Release Date: 5/2/06
- Corrected problem where a patient's middle name can cause non-matches
to an applications database for certain Data Drill extensions (i.e. Dentrix).
Version 3.9 Build 89
Release Date: 4/20/06
- Added internal premount SED option before layout capture to support SED
extensions that cannot mount in a separate process thread.
Version 3.9 Build 88
Release Date: 4/13/06
- Added TAKEN(YYYYMMDD) information to file produced by the "/t" command
line option.
Version 3.9 Build 86
Release Date: 4/6/06
- Added patient import options. This can import one or more patients (or
an entire database) based on the directory selected.
- Integrated new DiskBurner extension. This extension can be used to directly
burn CD/DVD discs or to export patient's images to a directory.
Version 3.9 Build 85
Release Date: 3/27/06
- Select all option was added to the print multiple images dialog.
- Taken date problem corrected when the user changes an image's extended
information in a layout and then saves the change when a taken date was not
original associated with the image.
- Additional text can now be added to all of the printout types (originally
only printing single images allowed the user to type additional text).
- Multiple line header and footer text now supported on printouts.
- Delete auto/quick calibrations option added. To delete an entry, simply
right click on an entry and then click on the "OK" button.
- Manual entry of patient index problem corrected on patient index screen.
Version 3.9 Build 82
Release Date: 3/17/06
- Removed DICOM tables item from the various menus. The DICOM tables have
been replaced by Apteryx's DICOM Reference Application.
Version 3.9 Build 81
Release Date: 3/3/06
- Improved status display for dataTAG searches.
- Improved status display for image note searches.
- Added starting and ending wildcards for dataTAG searches.
Version 3.9 Build 80
Release Date: 3/1/06
- Options added to automatically assign dataTAGs with images when they are
captured. New option is under dataTAGs in the Tools menu.
- Options added to modify dataTAGs for both a layout and each image in a
layout.
- dataTAG search window now stays up after the user selects which images
they want to view. Search window stays up until the user clicks on the "Close"
button.
- Taken date on spawned documents was left blank when an official taken date
was not assigned to the image. A change was made to take the inferred taken
date when the user has not officially assigned a taken date to an image/layout.
Version 3.9 Build 78
Release Date: 2/8/06
- Added ability to restrict prompting for teeth for certain sensor extensions
(e.g. pans and cephs).
Version 3.9 Build 77
Release Date: 1/11/06
- Changed interface with TWAIN devices to retrieve better error information
when scanning fails. The application would periodically display a "no error
really occurred" error even though an error actually did occur; this was
corrected to obtain better error information about why the scanning actually
failed.
Version 3.9 Build 76
Release Date: 12/28/05
- Added new image macro "resize size". Resizes an image to the indicated
dimensions (in/cm/mm). NOTE that measurements may NOT be accurate in the
resulting image due to this macro actually specifying the new dimensions
for the image. If either the width or height parameter is left blank, the
image will be resized with the proper aspect ratio. For example, an image
that is 5x10in will have the following sizes: ResizeSize(2.5x20) = 2.5x20in;
ResizeSize(2.5x0) = 2.5x5in; ResizeSize(0x20) = 10x20in.
Version 3.9 Build 75
Release Date: 12/27/05
- Added new feature to search image notes for keywords.
Version 3.9 Build 74
Release Date: 12/14/05
- Added the ability for a patient's DOB and sex to be exported when creating
multiple image documents.
Version 3.9 Build 73
Release Date: 12/12/05
- Additions made to export taken date for the various images in a spawned
multiple-image document.
Version 3.9 Build 72
Release Date: 12/8/05
- Corrected quick capture options for CliniView where sensor install error
might be displayed if the OCD system was not installed even though the user
clicked on a Sigma or OPD unit.
Version 3.9 Build 71
Release Date: 11/9/05
- Added options for CliniView build that will only initially add capture
toolbar button if the appropriate imaging extension has been installed (e.g.
Sigma button is only present if the Sigma extension has been installed).
Version 3.9 Build 70
Release Date: 11/9/05
- Added new '\t' command line option.
- Corrected problem with command line option processing.
Version 3.9 Build 69
Release Date: 10/7/05
- Maintenance release.
Version 3.9 Build 68
Release Date: 9/9/05
- Added "export patient list" option.
- Added option to auto-save an entire layout as a single image.
Version 3.9 Build 67
Release Date: 8/17/05
- Added passwording.
- Added secure logging.
- Corrected error when an external database contains more than 65K patients.
Version 3.9 Build 65
Release Date: 6/14/05
- Made correction to DICOM information submission of images
contained in a layout. Prior versions might store the information in such
a way that if the layout images were not stored before the layout was closed
that the DICOM information may be ignored.
Version 3.9 Build 64
Release Date: 6/7/05
- Floater View now records and utilizes last window placement.
Version 3.9 Build 63
Release Date: 6/2/05
- Added options to have sensor extensions indicate what type of image was
acquired. Previously images were sub-classified as PA images.
Version 3.9 Build 62
Release Date: 5/24/05
- Correction had to be made due to label property saving. Old label property
file format did not permit correct interpretation of each label's properties
leading to some label anomalies. New format more resilient to label property
errors. Note that old label properties are reset.
Version 3.9 Build 60
Release Date: 5/5/05
- Added new layout/zip file support that will improve performance of reading
layouts over the network.
- Corrected patient print information error when having one patient open,
opening the patient list, right-clicking on an image to bring up full-screen
view and then printing the image.
- Custom image extension buttons now correctly remember tooth numbers if
they are set by the invoked extension.
- Implant drawing corrected.
- Implant thumbnail drawing rotated so the implants are displayed top-down.
Version 3.9 Build 58
Release Date: 4/28/05
- Added functionality to prevent closure of layout capture when a non-threaded
sensor capture is invoked (i.e. Schick).
Version 3.9 Build 56
Release Date: 4/27/05
- New implant functionality implemented to support compressed, single-file
libraries.
Version 3.9 Build 55
Release Date: 4/21/05
- New implant functionality implemented.
- New Label View option added. This view enables magnifying and panning
operations when working with labels (especially implants and measurements).
The new feature is activated in the Image manu, context sensitive menus or
by pressing Ctrl+A when an image or layout is open.
- New DICOM option added to set specific institution information.
Version 3.9 Build 53
Release Date: 4/13/05
- Refined the implant overlay.
Version 3.9 Build 52
Release Date: 4/11/05
- Added option to permit storing open images to a DICOM server. This option
is different than the current DICOM store option in that the user does not
have to select which images they want to save to the server.
Version 3.9 Build 51
Release Date: 4/7/05
- Corrected problem with new SED name operations where it would try to invoke
the incorrect SED.
- Layout selection for DICOM storage now supports multiple image selection.
Version 3.9 Build 50
Release Date: 3/29/05
- Correction made for crash experienced on some computers when creating a
new layout. Problem was due to new overlay label update code trying to be
performed on empty layouts.
Version 3.9 Build 49
Release Date: 3/23/05
- Added implant overlay.
- Added implant library support. The new implants appear as a new label object.
The actual manufacturer implant libraries are not currently available online
but should be available for download in the next few business days.
Version 3.9 Build 47
Release Date: 3/4/05
- Added new options for naming conventions of digital x-ray extensions.
- CliniView: updated GE graphics.
Version 3.9 Build 46
Release Date: 2/22/05
- Added 144% quick selection option to overlays.
- Added ruler overlay.
Version 3.9 Build 44
Release Date: 2/1/05
- Added change taken date layout option for layouts.
- Corrected printed taken date on layouts.
Version 3.9 Build 43
Release Date: 1/27/05
- New Apteryx DICOM UID added.
- New functionality added to layout captures to allow freeing of hardware
devices.
- Correction made when changing tiles in the middle of a layout capture from
a scanner or imaging device extension.
Version 3.9 Build 39
Release Date: 1/6/05
- Corrected modification of images in layouts when performed from the capture
images dialog.
- Miscellaneous changes and fixes.
Version 3.9 Build 38
Release Date: 12/14/04
- Refinement of overlays calibration.
Version 3.9 Build 36
Release Date: 12/11/04
- Futher refinement of overlays.
- Added additional magification options by right clicking on overlays.
Version 3.9 Build 33
Release Date: 12/10/04
- Further refinement of the overlay measurements. Please note that the overlays
are still linearly spaced (and the measurements will be off in non-linearly
spaced pan images).
Version 3.9 Build 34
Release Date: 12/8/04
- New option added to only allow one overlay at a time (automatically turns
off old overlays when a new overlay is selected).
- Interference with label operations corrected when an overlay is displayed
in an image.
- Thickness of the various lines in the overlays made smaller to allow better
placement of the overlays.
- "550 Tome IJD" text added to the Tome overlay.
- New action mode added to the software so that overlays do not conflict
with labels. Overlays may be moved by selecting the "Overlay Movement" option
from the Action menu.
Version 3.9 Build 33
Release Date: 11/12/04
- Overlays added to the Labels menu. Overlays currently consist of overlays
for pan images.
Version 3.9 Build 31
Release Date: 10/28/04
- Maintenance build.
Version 3.9 Build 30
Release Date: 10/14/04
- Tooth control now automatically adjusts the size of the font used to draw
the tooth labels. This adjustment is primarily required for veterinary tooth
control layouts. New veterinary tooth controls are available in the tooth
control updater.
Version 3.9 Build 28
Release Date: 9/39/04
- Tooth numbers can now be displayed on the title bar of each image (enabled
by default).
- All options are now available for each button in the toolbox.
- Locking the toolbox now locks ALL of the buttons instead of just the primary
buttons.
- Popup button list now correctly displays on multiple monitor systems.
Version 3.9 Build 27
Release Date: 9/27/04
- Added new options when capturing a layout that permit flipping, rotating
and inverting of images directly from the layout capture screen.
Version 3.9 Build 26
Release Date: 9/23/04
- Added new support for auto-orientation of images when taken from imaging
device extensions when not captured in a context of a layout..
Version 3.9 Build 25
Release Date: 9/16/04
- Added support for suppressing "media ready" messages when scanning from
a scanner or TWAIN device.
- Added support for auto-orienting images when capturing from imaging device
extensions.
Version 3.9 Build 24
Release Date: 8/30/04
- Changed the "unsupported database version" message to the more appropriate
"read/write permission" error.
- Change the default requirement of the DOB field from "DATE ONLY" format
to "ANY FORMAT".
Version 3.9 Build 22
Release Date: 6/21/04
- Added new features to permit the user to specify the requirements for each
patient information field (i.e. ss number format). The new feature is available
in the application Options on the General tab
(Patient Definition Requirements button).
Version 3.9 Build 21
Release Date: 6/5/04
- Added options to the "Safety" tab that permit the archiving of the original
images when the user saves a modified image for a patient..
Version 3.9 Build 20
Release Date: 6/1/04
- Correction made to improper image association when capturing a layout..
Version 3.9 Build 19
Release Date: 5/25/04
- Integration of new drawing capabilities of various controls to make smoother
drawing of the interface.
- Correction made to directory creation of patients in non-English countries.
Version 3.9 Build 16
Release Date: 3/8/04
- Added functionality added permitting other application to retrieve patient
image information and direct opening of images.
Version 3.9 Build 14
Release Date: 2/10/04
- Additional fields added for DICOM related information.
Version 3.9 Build 12
Release Date: 2/8/04
- Additional calibration tools added. New Calibration popup added to the
application that permits the easy setting of calibrations and auto calibration
factors. New auto-calibrations added to permit calibration factors to be
automatically added to an image once it has been captured.
- Popup locations corrected when the application is being used on a monitor
to the left of the main monitor on a multi-monitor system.
- Better initially sized popups and corrections made to current popup size
adjustments when the popups are sized greater than 1/4 of the application
interface size.
- New calibration tools permit calibration to previous images as well as
allowing different calibrations to different size sensors from the same system.
Version 3.9 Build 11
Release Date: 2/4/04
- Additional DICOM information support added. Please note that you will need
to additionally update the DICOM.DLL and main application before the additional
DICOM information will be available.
Version 3.9 Build 10
Release Date: 1/28/04
- Correction made to odd reduction factors on large images.
Version 3.9 Build 9
Release Date: 1/21/04
- Correction made to memory leak that may occur when importing DICOM images
directly from a file.
Version 3.9 Build 8
Release Date: 12/10/03
- Maintenance release: Window's font is now used for various controls in
the interface; extended character sets now available for a wider range of
supported languages; new more efficient versions of interface controls added.
- DICOM print and print job support added.
- Tooltip functionality corrected corrected on the various thumbnail controls.
Version 3.9 Build 7
Release Date: 12/3/03
- Added DICOM print and print job options.
- Corrected DYNZAIP error that is displayed when importing images from a
memory card directly into a patient's record.
Version 3.9 Build 5
Release Date: 11/10/03
- Multiple registration numbers may now be entered into the same application.
Multiple registration number support permit the user to install the application
on a single computer and combine their licenses into a single installation
on their network.
Version 3.9 Build 4
Release Date: 11/3/03
- DICOM support added.
- Corrected problem with updating the patient database when the original
database files are deleted in their entirety and database caching is enabled.
Version 3.7 Build 4
Release Date: 6/16/03
- CliniViewXV build only: Allows three sensor buttons (Sigma, OPD, OCD) to
be placed on the toolbar..
Version 3.7 Build 3
Release Date: 6/4/03
- Significant redesign of how XrayVision interacts with patient information
bridged from another application, detections of duplicate patient information
(i.e. SS number, ID number) and actions taken when resolving patients.
Version 3.7 Build 1
Release Date: 5/16/03
- New registration number and licensing integrated.
- Quite a few internal changes.
- Correction made to auto-export browse button.
- Modifications made to ensure single-instance nature of the software.
- Lock toolbox option added.
- Upgrades where made to the "Add Sensor" utility.
- Open patient list now hides the thumbnail control when no patient's match
the search criteria.
- Taken date dialog resized to accommodate wider date controls.
- "Find images by date" option added. This option may be used to search the
entire patient database for images taken on a certain day.
- Registration upgrading support added to the software.
- When briding patient information from another application, XrayVision no
longer automatically opens ANY matching SS number to the one specified.
Version 3.5 Build 55
Release Date: 4/15/03
- Change made to support layout capture from the Schick hardware.
Version 3.5 Build 54
Release Date: 4/4/03
- Fixes crash that occurs when clicking on several of the browse buttons
throughout the application.
- Alternate painting/drawing setting is now forced to be applied when entering
the application.
- The "Continue To Use This Source" setting is now saved with the application
options so that it is remembered the next time the application is
run.
- The "Switch To Layout Capture Mode" option is now defaulted to on.
- Auto tile option now works on image opened from the patient rolodex.
Version 3.5 Build 53
Release Date: 3/8/03
- Option added to prevent
the image from being zoom-to-fit when brought up in a full-screen view.
Version 3.5 Build 52
Release Date: 2/13/03
- Dual monitor support
added.
- HIPAA compliant setting added
(enabled by default). Hides the patient's SS and ID numbers on the
interface as much as possible.
- Spot function's performance
drastically improved.
Version 3.5 Build 51
Release Date: 2/4/03
- New option management feature
added. Permits the creation of a common computer settings file that
can be used by other computers to use the same options that have been set
on another computer. Permits computers to share the same options without
having to manually set the options on each computer.
- New scroll indicators
used on graphic button lists.
Version 3.5 Build 49
Release Date: 1/27/03
- Modification made to the optimization
of adding patients. Previous optimization of patient creation resulted
in failures on some computers.
Version 3.5 Build 48
Release Date: 1/21/03
- Database caching feature
made a global setting (instead of a per computer setting).
- Buffering added to
configuration I/O (optimization).
- Buffering added to
Patient FMap I/O (optimization).
- New option added to the application
options that to enable/disable patient FMap validation. This is a
feature that can be used on heavy and encrypted networks to facilitate quicker
opening of patients.
Version 3.5 Build 47
Release Date: 1/6/03
- Database caching features added
to the application. This new feature is available under: Tools; Options;
Database Tab. This new option significantly reduces (almost to an
immeasurable time) the time required for handling patient database access. This
change has been made to accommodate: encrypted, heavily utilized networks;
very large databases (8000+ patients); dynamically changing databases (i.e.
10+ computers adding patients at the same time; wide area networks; and
other slow or heavy networks.
Version 3.5 Build 46
Release Date: 12/12/02
- Version information
option display and print added under the Help menu.
- Crash corrected when
changing between tiles when capturing in a layout.
- Memory improvements
when dealing with long patient name lists.
- Document template
option to automatically handle when images are too large to be handled
by Microsoft Word.
- Added new brightness/contrast
algorithm for images containing a lot of white (Overwhite).
- Angle measurement
label changed to only display one angle measurement.
- Calibration icon used
in toolbox corrected.
- Angle measurement
tool added to the toolbox.
- Auto export definition
names now appear in the toolbar tooltips.
- "DOB:" prefix
added when printing a patient's date of birth.
- Modified warnings
added when trying to save an image that was modified at the same time
by someone else on the network.
- Corrected printing
an image's filename when printing multiple images.
Version 3.5 Build 45
Release Date: 11/22/02
- Angle measurement
labels added.
Version 3.5 Build 44
Release Date: 11/16/02
- New multiple image
acquisition support added for capturing from multiple image TWAIN devices/sources.
Version 3.5 Build 43
Release Date: 11/12/02
- New feature added to automatically
associate image information returned by various imaging devices. Note
that not all imaging devices support the return of image capture information.
Version 3.5 Build 42
Release Date: 11/12/02
- Change made to correct if the
user fails to select a sensor system before trying to capture a sensor image. Even
if it looks like the sensor system is selected, it was not actually selected
until the user physically clicks on the system.
Version 3.5 Build 40
Release Date: 9/24/02
- Other application spawning
made easier to use. Please note that this will invalidate any previous
definitions that you may have. The underlying structure had to be
changed in order to support the new version and the two are completely incompatible.
- Layouts consisting
of all scanned images now listed under the Scanned Image type.
- Option added to prompt
for which database should be mounted when the Advanced Database / Mobile
Database extension has been installed.
Version 3.5 Build 39
Release Date: 9/24/02
- A new feature was added that
displays a small thumbnail view of an entire layout when viewing one of
the images in a layout. New images can be selected by clicking on
the various images in the layout overview.
Version 3.5 Build 38
Release Date: 9/22/02
- Change made for process
control return when XrayVision is invoked by another application via the
toolkit and the user cancels the create new patient processes.
Version 3.5 Build 37
Release Date: 9/13/02
- Added an Imaging
Device tab in the acquire single image dialog.
- Added new feature for
document template spawning that permits the documents to automatically
be saved in a folder with a unique filename and not deleted by XrayVision. Previously,
the document templates were generated in a temporary location and deleted
when the application was closed.
- An option was
added to the layout designer that permits all tiles in a layout to be
changed to a source at the same time instead of one at a time.
Version 3.5 Build 36
Release Date: 9/11/02
- New in-place magnification
tool added to the Actions menu.
Version 3.5 Build 35
Release Date: 8/26/02
- RESTRICTED OPERATION
ADDED: User license tracking override added to permit the system
to free up user licenses once they stop using the application. Their
configuration information is cached and utilized again the next time they
use the application.
- Added error
trapping for unsupported versions of JPEG compression in TIFF files.
Version 3.5 Build 34
Release Date: 8/25/02
- Added new features
to the File, Acquire menu to allow direct selection
of Image Device Extensions. This option also permits the placement of
a custom toolbar button for an Image Device Extension.
Version 3.5 Build 33
Release Date: 8/15/02
- New feature added
to print patient's DOB in both the image text as well as in the headers
and footers.
- Changed the maximum
sensor pause from 10 seconds to 30 seconds
Version 3.5 Build 32
Release Date: 8/3/02
- Changes made to various
sensor screens to support more sensor extensions.
Version 3.5 Build 31
Release Date: 7/25/02
- Date handling on "By
Listing" screens changed to provide modified/taken date handling
as well as sorting.
Version 3.5 Build 30
Release Date: 6/3/02
- New command line features
added.
- New support for image
capture invocation from remote applications.
Version 3.5 Build 28
Release Date: 3/28/02
- Adjusted the default
number of PACs for the CliniView release.
- Change "panoral"
to "panoramic"
- Added a warning message
when the user disables the "Toolbox Buttons" option on the Interface2
tab in the application options.
- Default CliniView
"Adaptive Normalize" button changed to "Auto B/C"
Version 3.5 Build 26
Release Date: 3/18/02
- Added new toolbar
icons for the CliniView application.
- Changed the toolbar
buttons for the CliniView application.
- Expanded toolbox size
(there are 6 new assignable buttons).
- New toolbar graphics
available for the custom toolbar.
- New toolbox buttons
available.
- Multiple language
changes now changes the text on the custom toolbar after the language
selection is made (and not the next time the application is opened).
- Multiple language
toolbar graphics - added transparent bitmap drawing to make the icons
looks more presentable in Win2K/WinXP.
Version 3.5 Build 25
Release Date: 3/17/02
- New option to have
the ability to select ANY function for each of the buttons in the toolbox.
- Transparent bitmap
drawing added to make the icons look more presentable in Win2K/WinXP.
- Custom toolbars will
now display text on the buttons if the large toolbar option is enabled.
- Change the default
content of the customize toolbar.
- Made the default installation
display only the custom toolbar and not both the custom toolbar and the
main toolbar.
Version 3.5 Build 23
Release Date: 2/20/02
- Open file dialog for
a patient's image displays the respective image type icons in gray if
there are no images of that type in the patient's record.
- CliniViewXV OEM defaults
the auto-layout capture mode to enabled.
- "Discard"
button now changes its text depending on the function (e.g. "Discard
Changes", "Discard Image", "Discard Group").
- Full screen view now
zoom-to-fit the images upon initial display.
- Spot magnify feature
now remembers the last selected magnification factor.
- Relative density dialogs
now appear in the lower right-hand corner of the screen.
- Calibration dialog
now defaults to mm measurement.
- New emboss feature
added that automatically uses default embossing values (does not display
a dialog).
Version 3.5 Build 21
Release Date: 8/29/01
- Feature added to remember
the last image type selection on the "Open Patient Images" dialog.
Version 3.5 Build 20
Release Date: 8/22/01
- "Update Patient
Directory Names" option added to convert patient directories from
firstname,lastname to lastname,firstname.
- Update All Patient Filenames" option
added to force all patient's file maps to be updated. This option
is primarily used to update the taken dates associated with version 3.1
image files.
Version 3.5 Build 19
Release Date: 6/16/01
- New graphic buttons
used to conform to Win2000 new dialog colors and graphic positions.
- OK and Cancel button
graphics changed to Apteryx standard graphics.
- "Select video
type" option added under Tools to select what type of real-time video
device should be used.
- Added support for
selecting the DriveVideo video capture extension.
Version 3.5 Build 18
Release Date: 5/7/01
- Add vertical or horizontal
tile option added to layout designer.
- Rotate tile option
added to layout designer.
- Reduced the number
of modified image warnings reported when viewing a layout.
- Real layout image stamps option
added to application options. Instead of creating a generic representation,
this option will create layout stamps containing actual images.
- Correction made to
prevent tooth selections made under quick capture from jumping between
adult to deciduous.
- Image's tooth display
improved (automatically switches to deciduous if no adult teeth are associated
with the image).
- If creation date of
an image is greater than its modified date (i.e. an image file was copied
from anther disk), then created file time is changed to the modified date.
- "Create Patient
CD or Disk" option added to the patient utilities.
- Correction made to
sorting by image size when displaying a database statistics.
- Layout display in
full-screen view or floater view from any of the thumbnail controls (i.e.
open patient, patient image bar, tooth images).
Version 3.5 Build 17
Release Date: 4/25/01
- Sensor delay option
was added to enable a delay between sensor captures in a layout.
- Automatic title option
added when opening images.
- Now all of the thumbnail
controls will sort their images by the taken or modified date specification
in the application options.
- Multi-line tooltips
added to all thumbnail controls.
- Taken date now depends
on the oldest associated date with a file (support for recreating or moving
patient databases).
- Improved preview option
on Open File Dialog
Version 3.5 Build 16
Release Date: 4/2/01
- Foot pedal activation
support added to application
- Option to enable wether
or not the application plays the "Sensor Failure" sounds on
user abort
Version 3.5 Build 14
Release Date: 3/14/01
- Image thumbnail display
enabled when scrolling through the patients in the patient index
- Correction for deciduous
tooth associations when capturing sensor images
- Taken date handling
improved for files/images copied from storage media or tape backups
- Disabled custom toolbar
button's appearance made to resemble other disabled toolbar buttons
- When hitting <ESC>
during sensor capture, the "Sensor Failure" audible is no longer
played
- Additional DLL checking
performed at application startup
Version 3.5 Build 12
Release Date: 3/11/01
- New override features
were added to the application.
Version 3.5 Build 11
Release Date: 2/19/01
- Correct XVa3 crash
on exit when TCP/IP is not installed on the computer.
Version 3.5 Build 10
Release Date: 2/07/01
- Addition of tracking PAC licenses
by user (instead of computer) added. The system administrator can
now choose how PAC licenses are tracked.
- Quick scan feature
added
- ArchiveIT support
added
- Advanced Database
support added
- Customizable toolbar
support added
- Menus changed
- DOB and Sex added
to patient information
- Image storage format
reformatted to remove the STB16 option
- Better patient name
checking implemented
- Ability to limit the
number of patients presented in the MRU patient list
- Application options
reformatted
- Discuss@apteryx option
added
- False duplicate registration
number error messages corrected.
- Functionality changes
to various dialogs made
- Internal changes made
to increase performance
- Wording changed on
several options to improve readability
- Patient sub-directories
now created by lastname, firstname
- .DOC and .DOT document
template support added
- Printing patient list
support added
- Tooth association
with Nobody images added
- Layout tile/image
auto type and teeth associations added
- A layout's type is
now automatically determined
- New layouts (created
under layout manager) now appear first in the MRU layout list
- The user can now specify
what type of information is to be prompted for after an image capture
- User can now indicate
what date is to be displayed on an image's title bar (i.e. modified date,
taken date, etc.)
- Several bugs corrected